Donnerstag, 28. Oktober 2010

PowerPoint 2003 and 2007 Resolution picture export

How to change the resolution of a slide that you export as a picture in PowerPoint

link to Microsoft

Mittwoch, 20. Oktober 2010

Windows 7 deploying images with imagex.exe

An excellent german manual you find here
http://wiki.winboard.org/index.php/Windows_7_verteilen

This Blog is a short English version of this manual.


look also
http://technet.microsoft.com/de-de/library/cc749092%28WS.10%29.aspx
http://www.tecchannel.de/pc_mobile/windows/2023629/windows_7_automatisch_installieren/
With special information for AutoUnattend.xml.



Create a "Windows Preinstallation Environment (WinPE)

You need
- Windows Automated Installation Kit (WAIK) für Windows 7 and
- Windows 7 Install-DVD

Create the iso file

Copy imagex.exe from WAIK to your WinPE iso file

for more information to create a WinPE
http://wiki.winboard.org/index.php/Windows_7_verteilen


Create Image

- Install Windows 7 on a fresh system


- Create an account and type in the computername

- Go run

"c:\windows\system32\sysprep\sysprep.exe"

System Preparation Tool:
-System Cleanup Action:
--Enter System Audit Mode
-Generalize is not active
-Shutdown Options
--Reboot

OK

Reboot the System

Now the system is in the audit modus.

Install all drivers and software you need.
Be aware not to close the System Preparation Tool window

Then you finished with installing drivers and software change the System Preparation Tool

System Preparation Tool:
-System Cleanup Action:
--Enter System Out-of-Box Experience (OOBE)
-Generalize is active
-Shutdown Options
--Shutdown

The System is finished for the next step.

Start the computer with the WinPE

Insert your WinPE CD and boot from CD

A command Prompt will be shown

Change device there you find your imagex.exe
For example
d:

imagex /compress maximum /capture c: c:\MyWin7.wim "Windows 7" /verify

Explanation:
/compress maximum -
record with less data volume
/compress fast -
for fast recording
/capture c: device C:\ - is recording-

c:\MyWin7.wim "Windows 7" -
Name of image file
/verify - proof the whole thing




Use the Image

start with WinPE-C
- If you already create a partition
 format c: /q
you format C: in quick modus


- If you had a empty harddisk use the diskpart tool
diskpart
select disk 0
clean
create partition primary size=20000
select partition 1
format fs=ntfs label="Win7" Quick
assign letter=c
active
exit

with help you get information


- Change to there you find imagex.exe
For example you will find it in
d:

imagex /apply F:\MyWin7.wim 1 c:

Explanations:
/apply - we will use the image
F:\MyWin7.wim - your image is in F:
1 - this is the first image
C: the image will paste on c:

The image will be copied to c:
End the program with "exit"


Hint:
I got a 
"bootmgr missing" then I started the cloned Windows 7.
 
I started with the Win7 install DVD.
 

1. "Repair your Computer"

2.Select 
Startup Repair



- Alternatively you can type in in the comand prompt:

bootrec /rebuildbcd



- If Bootrec cannot locate any missing Windows installations,
you must remove the BCD store, and then you must re-create it.
To do this, type the following commands in the order shown below:
(Remember to press ENTER after each command)

bcdedit /export C:\BCD_Backup

ren c:\boot\bcd bcd.old

bootrec /rebuildbcd

- Restart the computer.


Sometimes following helps, in case Linux was installed:bootrec /fixmbr
bootrec /fixboot
bootrec /RebuildBcd




- Maybe you need another
Startup Repair
by booting from Install-DVD



see for bootrec
http://cyberst0rm.blogspot.com/2007/04/how-to-fix-bootmgr-is-missing-in.html


How To Rebuild the BCD in Windows
http://pcsupport.about.com/od/fixtheproblem/ht/rebuild-bcd-store-windows.htm

Freitag, 17. September 2010

Windows XP Bluescreen Stop 0xA (0x40009E1,0, 0x804D9B64)

Dell Notebook, 4 years old
IRQL_Not_LESS_OR_EQUAL
Bluescreen Stop 0xA (0,0, 0x804D9B64)

Solution:
Start Notebook with Key F8
Save Mode
Open Device Manager
Inactivate Intel WLAN Driver

Start Windows Normal

De-install and install newest Driver for WLAN
EndNote "invalid class string"
This is an endless story (update March 2012)

You get
"invalid class string" if you try to open/insert citation from EndNote in MS Word.

Easy solution is, if you never open EndNote. In this case close word and open EndNote. Open Word again.
http://www.endnote.com/support/faqs/enfaq29.asp

If this does not work you have probably install EndNote over a old EndNote version. The EndNote Technical Service gave me a solution.


1.(March 2012) this is an almost unbelievable story!
EndNote X1 and later on Windows Vista/7

http://www.endnote.com/support/faqs/cwyw/faq13.asp
  1. Close all open programs.
  2. Go to the EndNote program folder. This is typically
    C:\Program Files\EndNote XX
    or
    C:\Program Files (X86)\EndNote XX
    Where XX represents your version of EndNote
  3. Right click on EndNote.exe and select "Run as administrator."
  4. With EndNote open, click on the Start Menu. In the search box type "regedit" (without quotes) and hit enter on your keyboard to launch the Registry Editor.
  5. Expand the "HKEY_CLASSES_ROOT" folder and locate the key:
    "EndNote11.AddinServer" (for X1)
    "EndNote12.AddinServer" (for X2)
    "EndNote13.AddinServer" (for X3)
    "EndNote14.AddinServer" (for X4)
  6. Right Click on the AddinServer key and select Permissions.
  7. Click Advanced. Then click Add.
  8. In object name, type "Everyone" (without quotes) and click Ok.
  9. In the Permissions entry window, go to the Delete row. Click Deny and then choose OK.(Really you had to deny the permission to delete)
  10. Close the Registry Editor and close EndNote.
  11. Start EndNote and your word processor normally and try the tools.


2. Here my E-Mail to EndNote
(Sept 2010)

Dear EndNote

Error: Invalid Class String.

Endnote FAQ Question 29: "... close Word and open again." does not work.

----------------------------
Reply from EndNote Technical Support :

Dear Dieter Steinmetz,

Installing EndNote X3 as an administrator should still work as long as the user has full read/write/modify rights to the following registry locations:
HKEY_CURRENT_USER\Software\ISIResearchsoft
HKEY_CURRENT_USER\Software\Microsoft\Office\11.0\Word
HKEY_CURRENT_USER\Software\Microsoft\Office\Word\Addins

Additionally, you will want to uninstall any prior versions of EndNote.

If you wish to do a full, clean install. Please do the following:

First, make sure to back up any library files (both the .enl and the .data) that may be saved in your Program files/EndNote folders.

Do the same for any styles, connections, or filters you may have saved in the EndNote folders.

Now uninstall any versions of EndNote you have on your computer. Next do the following:

1) Quit all applications.
2) Go to Start in the lower left hand side of your monitor and click Run
3) Type regedit then press ok
4) Expand HKEY_CURRENT_USER/Software/ISIResearchsoft/
5) Delete the EndNote folder and it's contents.
6) Expand HKEY_CURRENT_User/Software/Microsoft
7) Right Click the Office folder and choose to Export.
8) Name the file addin keys and save the file to your desktop
9) Expand the Office/11.0 folder
10) Delete the Word folder in the 11.0 folder.
11) Expand HKEY_CURRENT_USER/Software/Microsoft/Office/Word folder.
12) Delete the Addins folder.

Now delete the following folders and files:


C:\Documents and Settings\[Your user name]\Application Data\EndNote\
C:\Program Files\Common Files\ResearchSoft\
C:\Program Files\Common Files\Thomson ResearchSoft\
C:\Program Files\EndNote [version]\

Also delete any CWYW files you find in C:\Documents and Settings\[Your user name]\Application Data\\Microsoft\Word\STARTUP

Now you can re-install EndNote X3. Make sure to have full administrative rights when you do this and you should disable any antivirus/spyware program(s) you may have running.

If you need further assistance with this issue, please let me know by replying directly to this e-mail.

Donnerstag, 1. Juli 2010

Lexmark E352DN Install New PC and Resetting Photo Conductor Counter

To install new Photo Condictor (PC) and reset the Lexmark E352DN Photo Conductor Counter
(Fotoleiter Zähler)

Lexmark E352DN
Buttons
Cancel-left-OK-right-back-next
  1. Turn printer off
  2. Put in the new Photo Conductor (PC)
  3. Close front door
  4. Press and hold "OK" and "Back" while turning printer on
  5. Replace Photoconductor appears
  6. Press "Next"
  7. "Reset PC Cnt"
  8. "OK"
  9. "=Reset" appears
  10. "OK"
  11. "Resetting PC Cnt Value"
  12. Turn Printer off
  13. Turn printer on.

Donnerstag, 18. Dezember 2008

Dell Optiplex 755 Windows XP Install Image

Install Windows XP.

- Enter Bios (F2)
- Drivers
- SATA Operation
- RAID Autodetect / ATA
- Save and leave Bios

- Install Windows XP
- F6 to install SATA Drivers
(Drivers on Dell Support Page)
-External USB-Floppy Drive with SATA-Drivers


Copy Harddisk

Create Install from Master PC
-remove Harddisk from Master PC
- put master harddisk in 2nd PC in slot SATA-2
- Activate SATA-2 in BIOS (F2)

- Start PC with Norton Ghost 2003 on external USB Floppy Drive
- "Ghost -noide"
- Copy Harddisk to 2nd PC harddisk


-Start 2nd Harddisk
- Deactivate SATA-2 in BIOS (F2)
- Activate your Windows XP
- NewSID
(Computername, IP-Address)

Donnerstag, 13. November 2008

Elgg Social Networking - Suse - Apache

Installation Elgg Social Networking Software

Open Suse Linux 11.0
Elgg 1,1
http://elgg.org/index.php

Error:
The install script redirects me to "action" when it should be "actions"
http://community.elgg.org/pg/pages/view/23/


Solution from

http://enarion.net/web/apache/htaccess/mod_rewrite-on-suse/

- activate module_rewrite -> yast2
- .htaccess -> RewriteBase //
- /etc/apache2/default-server.conf -> AllowOverride All